App store
Download now
Microsoft Store
Coming soon
0854AGLVCHVG
|
Shipping Notice |
Ships within 1 business day |
|---|---|
|
Shipping |
|
|
Warranty |
5 year manufacturers warranty. |
|
Return Policy |
45 Day Easy Returns |
|
Sensor Measures |
Wind Speed, Current Wind Speed, Average Wind Speed, Maximum Wind Gust, Temperature, Barometric Pressure, Delta-T, Density Altitude, Dew Point Temperature, Globe Temperature, Accumulated Heat Load Units (AHLU), Heat Load Index (HLI), Heat Stress Index, Naturally Aspirated Wet Bulb Temperature, Relative Humidity, Temperature-Humidity Index (THI), WBGT (Wet Bulb Globe Temperature), Wet Bulb Temperature (Psychrometric), Wind Chill, Wind Direction, and Pressure Trend |
|---|---|
|
Product Features |
|
|
Includes |
|
| SENSORS | ||||
|---|---|---|---|---|
| SENSORS | ACCURACY | RESOLUTION | SPECIFICATION RANGE | NOTES |
| Wind Speed |Air | Larger of 3% of reading, least significant digit or 20 ft/min Speed | 0.1 m/s 1 ft/min 0.1 km/h 0.1 mph 0.1 knots 1 B* 0.1 F/S* |
0.6 to 40.0 m/s 118 to 7,874 ft/min 2.2 to 144.0 km/h 1.3 to 89.5 mph 1.2 to 77.8 knots 0 to 12 B* 2-131.2* |
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller |
| Ambient Temperature | 0.9 °F 0.5 °C |
0.1 °F 0.1 °C |
-20.0 to 158.0 °F -29.0 to 70.0 °C |
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits. |
| Globe Temperature | 2.5 °F 1.4 °C |
0.1 °F 0.1 °C |
-20.0 to 140.0 °F -29.0 to 60.0 °C |
Temperature inside 1in|25 mm black powder coated copper globe converted to Tg equivalent for standard 6 in|150 mm globe. Closest equivalence obtained with airflow greater than 2.2 mph|1 m/s. |
| Relative Humidity | 2%RH | 0.1 %RH | 10 to 90% 25°C noncondensing | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
| Pressure | 1.5 hPa|mbar 0.044 inHg 0.022 PSI |
0.1 hPa|mbar 0.01 inHg 0.01 PSI |
25°C/77°F 700-1100 hPa|mbar 20.67-32.48 inHg 10.15-15.95 PSI |
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
| Compass | 5° | 1° 1/16th Cardinal Scale |
0 to 360° | 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout. |
| CALCULATED MEASUREMENTS | |||
|---|---|---|---|
| MEASUREMENT | ACCURACY (+/-) | RESOLUTION | SENSORS EMPLOYED |
| AHLU | AHLU Accuracy derived from HLI accuracy accumulated over time. | 1.0 | Wind Speed, Temperature Globe Temperature, Relative Humidity |
| Altitude | typical: 23.6 ft/7.2 m from 750 to 1100 mBar max: 48.2 ft/14.7 m from 300 to 750 mBar |
1 ft 1 m | Pressure, User Input (Reference Pressure) |
| Barometric Pressure | 0.07 inHg 2.4 hPa|mbar 0.03 PSI |
0.01 inHg 0.1 hPa|mbar 0.01 PSI |
Pressure, User Input (Reference Altitude) |
| Crosswind & Headwind/Tailwind | 7.1% | 1 mph 1 ft/min 0.1 km/h 0.1 m/s 0.1 knots |
Wind Speed, Compass |
| Density Altitude | 226 ft 69 m |
1 ft 1 m | Temperature, Relative Humidity Pressure |
| Dew Point | 3.4 °F 1.9 °C 15- 95% RH. Refer to Range for Temperature Sensor |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| Heat Index | 7.1°F 4.0°C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| HLI | 2.7 | 1.0 | Wind Speed, Temperature Globe Temperature, Relative Humidity |
| Outdoor Wet Bulb Globe Temperature (WBGT) | 1.3 °F 0.7 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature Globe Temperature, Rative Humidity, Pressure |
| Probability of Ignition (PIG) | PIG Accuracy dependent on proximity of inputs to reference table steps. | 10% | Temperature, Relative Humidity |
| THI (NRC) | 1.5 °F 0.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| THI (Yousef) | 2.3 °F 1.3 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| Thermal Work Limit (TWL) | 10.9W/m2 | 0.1 °F 0.1 °C |
TWind Speed, Temperature Globe Temperature, Relative Humidity, Pressure |
| Wet Bulb Temperature - Psychrometric | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity Pressure |
| Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) | 1.4 °F 0.8 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure |
| Wind Chill | 1.6 °F 0.9 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature |
| ADDITIONAL PRODUCT INFO | |
|---|---|
| Display & Backlight | Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight. |
| Response Time & Display Update | Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes. |
| Data Storage & Graphical display Min/Max/Avg History | Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points. |
| data Upload & Bluetooth Data Connect Option | Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC). |
| Clock/Calendar | Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
| Auto Shutdown | User-selectable – Off, 15-60 minutes with no key presses. |
| Languages | English, French, German, Spanish. |
| Certifications | CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards. |
| Origin | Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B. |
| Battery Life | AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use. |
| Shock Resistance | MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller. |
| Sealing | Waterproof (IP67 and NEMA-6) |
| Display & Battery Operational Temperature Limits | 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading. |
| Storage Temperature | -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C. |
| Size & Weight | 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included) |
Implement an effective management plan based on objective and accurate THI, HLI and AHLU measurements at the pen level with Kestrel. Rugged hand-held meter can also be mounted with included hardware for longer term monitoring of heat events.
The Kestrel 5400 Cattle Heat Stress Tracker offers micro-climate measurement and monitoring at the pen or yard location. Contains a built-in Globe Temperature sensor and complete cattle-specific calculations. Measure THI and HLI and track AHLU based on easy-to-input herd and pen parameters. Perform spot checks or mount in place with the included vane mount accessory to track AHLU for months. LiNK capability allows remote access to current and logged data from your iOS or Android mobile device. Mount a mobile data equipped tablet nearby to send mobile alerts even when you’re not on-site. Designed by Kestrel with input from some of the world’s most respected experts in cattle heat stress, the Kestrel 5400 Cattle Heat Stress Tracker is designed to help you MEASURE and MANAGE your herd’s heat stress, ensuring you MAXIMIZE your bottom line.
6.540,00 NOK
perfect
Highly recommended, excellent service!
For LiNK enabled models only
Download now
Coming soon
Reviews by our customers
The equipment are in new and good condition. The shipping are really fast after making a payment, they send a package in next day. I am ordering product from Thailand. To be honest after comparing price, Extreme meter LLC is the best price in product and shipping fee.
I needed urgent for my K2 winter expedition. I was on the last min and needed the goods to be sent in Iceland. Their chat online worked 100% and I was able to add on one extra peace even after I checkout. They send with UPS same day and I had the package 3 days later here in Iceland. Extreme Meters works and has good service I recommend them.
I ordered the Kestrel 3550FW meter. Received email notifications reporting the progression of my order up to delivery, which was much quicker than I'd expected. Couldn't be more pleased with the product and service.
The service was prompt and cordial. The Kestrel is used to measure wind velocity and temperature when applying pesticides for agriculture crop production. It is also used to measure weather conditions for livestock comfort.
Extreme Meters answered ALL my questions, - were totally professional - were EXTREMELY respectful to me - were a REAL pleasure to chat with ALL BEFORE I PURCHASED THEIR PRODUCTS MOST SINCERE THANK YOU AND APPRECIATED
The website was easy to navigate and placing an order was effortless. Shipping was extremely quick. My order was in my mailbox before I knew it. I started to use the meter immediately; it is excellent for my needs.