{"product_id":"kestrel-rh-calibration-kit-0802","title":"Kestrel RH Calibration Kit","description":"\u003cp\u003e\u003cstrong\u003eKestrel RH Calibration Kit (Part #0802)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKeep your Kestrel weather meter performing at peak accuracy with the \u003c\/span\u003e\u003cspan\u003eKestrel Relative Humidity (RH) Calibration Kit\u003c\/span\u003e\u003cspan\u003e. Designed for field and laboratory recalibration, this kit allows you to restore the accuracy of your Kestrel’s humidity sensor whenever needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKit Includes\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThree clear, sealable calibration containers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOne container of \u003c\/span\u003e\u003cspan\u003emagnesium chloride\u003c\/span\u003e\u003cspan\u003e calibration salt\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOne container of \u003c\/span\u003e\u003cspan\u003esodium chloride\u003c\/span\u003e\u003cspan\u003e calibration salt\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAn insulated carrying case to securely store all components and maintain a stable calibration environment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCompatible With\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe RH Calibration Kit is designed for use with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAll Kestrel 5000 Series meters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAll discontinued Kestrel 4000 Series meters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKestrel 3500\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKestrel 3000\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ePerform Accurate Field Recalibration\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit allows you to perform dozens of humidity sensor recalibrations in the field, helping ensure your Kestrel continues to operate within factory specifications. When distilled water is used as directed, the kit can be used for an unlimited number of calibrations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe included instruction manual provides detailed, step-by-step guidance through the entire calibration process. Plan on approximately \u003c\/span\u003e\u003cspan\u003etwo days\u003c\/span\u003e\u003cspan\u003e to complete the procedure, as adequate stabilization time is required for the most accurate results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUpdated Calibration Procedure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor best performance, Kestrel has updated the recommended calibration process:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003ePrepare the calibration salt solutions according to the instructions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003ePlace the Kestrel in the first calibration container and allow it to stabilize for \u003c\/span\u003e\u003cspan\u003e24 hours\u003c\/span\u003e\u003cspan\u003e before running the first calibration routine.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAfter completing the first calibration, move the Kestrel to the second calibration container and allow it to stabilize for an additional \u003c\/span\u003e\u003cspan\u003e24 hours\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRun the second calibration routine to complete the process.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eAllowing the meter to stabilize for the full 24-hour periods ensures the proper humidity environment is achieved, resulting in significantly improved calibration accuracy. Based on testing, it is recommended to calibrate \u003c\/span\u003e\u003cspan\u003eonly one Kestrel meter at a time\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional Information\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003ePart Number:\u003c\/span\u003e\u003cspan\u003e 0802\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSKU:\u003c\/span\u003e\u003cspan\u003e 0802\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNSN:\u003c\/span\u003e\u003cspan\u003e 6660-01-560-0929\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eWeight:\u003c\/span\u003e\u003cspan\u003e 1.5 lbs (680 g)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eCountry of Origin:\u003c\/span\u003e\u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eA PDF version of the Kestrel Calibration Kit instructions is also available for reference.\u003c\/span\u003e\u003c\/p\u003e","brand":"Kestrel","offers":[{"title":"Default Title","offer_id":519271073,"sku":"0802","price":2653.0,"currency_code":"THB","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0344\/1457\/files\/4581602C-3AF1-4F1E-8355-8FC7FD194FD8.webp?v=1783778490","url":"https:\/\/www.extrememeters.com\/en-th\/products\/kestrel-rh-calibration-kit-0802","provider":"Extreme Meters LLC.","version":"1.0","type":"link"}