Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel 5500AG Agriculture Weather Meter - ExtremeMeters.com
Kestrel

Kestrel 5500AG Agriculture Weather Meter

0855AGHVG

Regular price $319.00 USD
-4 in stock

Free Expedited Shipping in the USA* | Typically ships same / next business day


Agriculture production requires local, site specific information regarding indoor climates and outdoor environments.

The Kestrel 5500AG is your comprehensive meter for condition monitoring and record keeping on the farm, ranch, or in the field. The Kestrel 5500AG provides you with data for risk identification, environment assessments, and action plan development. This meter includes THI, compass for direction and Delta T, an additional measurement to aid spraying applications.

Get the environmental data you need for livestock and crop production and other farm and ranch activities.This lightweight, handheld, multi-function meter can be used inside and out for barn/facility condition assessments to spraying decisions where both wind speed and direction must be recorded. This comprehensive meter will deliver spot measurements, log and store data, and aid in auditing and record keeping. The Kestrel 5500AG is easily carried in a pocket or glove box and is ready to help whenever and wherever needed. Its rugged build and waterproof case mean it can work as hard as you do. Be prepared: be informed of local and micro-climate environments at your site. 

Clip the Kestrel 5500AG into the optional Kestrel 5 Series Rotating Vane Mount and you have a sturdy weather station that can be left in place for days or weeks.


FREE EZ Returns Free Shipping in the USA 5 Year Manufacturers Warranty
Spray Management

The Kestrel 5500AG provides Delta T measurements to aid in assessing acceptable spraying conditions and ensure you're within guidelines. Based upon ambient temperature and dew point, Delta-T provides guidance on the evaporation rate of sprayed chemicals to help you select the right spray nozzle. The compass provides direction to minimize spray drift. The Kestrel 5500AG calculates and logs on-site Delta T, wind speed, and direction without any additional user input. When combined with the Kestrel’s average wind and max wind gust measurements, agriculture professionals can ensure they spray safely, every time. Use an accessory carry pouch to keep your Kestrel handy on your belt, ready to go before any spraying operations.

Heat Stress Management with THI:

THI(Temperature-Humidity Index)  has been used for decades as a measure to classify heat stress risk in many livestock production and transportation operations. This measurement includes both temperature and relative humidity and is a basis for both strategic and tactical management practices which benefit animal health, productivity and well-being. The Kestrel 5500AG calculates and logs on-site THI based on user selection of either the NRC(National Research Council, 1971) or Yousef(Yousef, 1985) accepted THI calculations. Objective and accurate site-specific measurements are critical to ensuring a heat stress management strategy that is cost effective; and they're at your fingertips with the 5500AG.

Barn / Housing Ventilation Assessments:

Regardless of the type of barn/house design all livestock require proper ventilation and air movement to maximize health, growth, and comfort.  The Kestrel 5500AG provides wind speed and air flow measurements to quickly quantify air movement in the vicinity of livestock, locate drafts, measure fan effectiveness and confirm duct discharge velocity. Volume air flow takes duct shape and dimensions into account and allows for accurate comparison of various locations in a system. No calculator is needed to determine airflow with the Kestrel 5500AG – a few quick menu picks and built-in averaging gives you accurate readings instantly.

Microclimate, Harvest and Storage Conditions:

Many livestock professionals also grow and store grains, hay and other feedstuffs. The Kestrel 5500AG can measure micro-climates around the farm to determine where mold and disease may be a problem, ensuring conditions are right for harvesting, drying, and storage. Leave the Kestrel 5500AG in place anywhere in the field, barn or greenhouse to get a graphical history of overnight conditions, (the Kestrel 5 Series Rotating Vane Mount and a ¼-20 camera clamp or tripod makes it easy).

Choose Kestrel LiNK Option to Add the Power of Apps:

LiNK is Kestrel’s wireless data communication system, powered by Bluetooth® low energy. Choose the Kestrel 5500AG with LiNK option and you get full iOS, Android, PC and Mac app support.  See real-time readings on your phone or tablet on a customizable dashboard up to 100’ away (line of sight). Download stored data from your Kestrel to save or share it. Plus, you can update the firmware on your Kestrel when improvements are released.

Note:  Bluetooth® low energy is built into all recent iOS and Android devices. PC and Mac connectivity require purchase of a Kestrel LiNK USB Dongle. Non-LiNK units can be connected to PC’s and Mac’s, but NOT phones and tablets, using the Kestrel USB Data Cable.

Built for Agriculture Use:

  • Rugged (drop tested to MIL-STD-810G standards – 10 drops from 4’).
  • Waterproof and dustproof (sealed to IP67 standards – 30’ submersion to 3’).
  • Small – carry in your pocket or store in your glove box.
  • High visibility case to avoid loss.
  • Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for use in low-light conditions.
  • Airflow impeller can be field-replaced without tools if damaged – patented!
  • Protective pouch, neck lanyard and Lithium AA battery included.
  • 5-year warranty.
  • Handheld, portable, data logger with on-screen graphing and measurement statistics.
  • Optional LiNK connectivity powered by Bluetooth® low energy provides wireless communication to mobile devices and computers.
  • Kestrel COC regarding accuracy of measurements

Measurements:

  • Air Flow
  • Wind Speed 
  • Altitude
  • Barometric Pressure
  • Crosswind
  • Delta T
  • Density Altitude
  • Dew Point Temperature
  • Wind / Air Direction
  • Headwind / Tailwind
  • Heat Stress Index
  • Relative Humidity
  • Station Pressure (Absolute Pressure)
  • Temperature
  • THI 
  • Wet Bulb Temperature (Psychrometric)
  • Wind Chill

Who's Using the Kestrel 5500AG Agriculture Weather Meter:  

  • Dairy Producers
  • Crop Growers
  • Crop Sprayers
  • Crop Dusters
  • Poultry Growers
  • Swine Operations
  • Livestock Processors
  • Veterinarians
  • Nutritionists 
  • Ag Consultants
  • Researchers

Models & SKUs:

  • Kestrel 5500AG Agriculture Weather Meter: 0855AGHVG
  • Kestrel 5500AG Agriculture Weather Meter with LiNK: 0855AGLVHVG

Includes:

  • Neck Lanyard
  • AA Lithium Battery (Average Life 400 Hours)
  • Protective Drawstring Pouch
  • Instruction Manual 
  • Five Year Warranty
  • Tips for Taking Accurate Measurements

KESTREL 1000-3500 SERIES SPECIFICATIONS

KESTREL 1000-3500 SERIES  SENSORS

SENSOR

ACCURACY (+/-)

RESOLUTION

SPECIFICATION RANGE

NOTES

Wind Speed |Air Speed

Larger of 3% of reading, least significant digit or 20 ft/min

0.1 m/s 1 ft/min

0.1 km/h

0.1 mph

0.1 knots 1 B

0.6 to 40.0 m/s 118 to 7,874 ft/min

2.2 to 144.0 km/h

1.3 to 89.5 mph

1.2 to 77.8 knots 0 to 12 B

1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to

0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy

-1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH |7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller.

Ambient Temperature

0.9 °F

0.5 °C

0.1 °F

0.1 °C

-20.0 to 158.0 °F

-29.0 to 70.0 °C

Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions.

Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.

Relative Humidity

3%RH

0.1 %RH

5 to 95% 25°C non-condensing

To achieve stated accuracy, unit must be permitted to equilibrate to external

temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.

Pressure

1.5 hPa|mbar

0.044 inHg

0.022 PSI

0.1 hPa|mbar

0.01 inHg

0.01 PSI

25°C/77°F

750-1100 hPa|mbar

22.15-32.48 inHg

10.88-15.95 PSI

Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000

mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

CALCULATED MEASUREMENTS

MEASUREMENT

ACCURACY (+/-)

RESOLUTION

SENSORS EMPLOYED

Altitude

typical: 23.6 ft/7.2 m from 750 to 1100 mBar max: 48.2 ft/14.7 m

from 300 to 750 mBar

1 ft

1 m

Pressure, User Input (Reference Pressure)

Barometric Pressure

0.07 inHg

2.4 hPa|mbar

0.03 PSI

0.01 inHg

0.1 hPa|mbar

0.01 PSI

Pressure, User Input (Reference Altitude)

Delta T

3.2 °F

1.8 °C

0.1 °F

0.1 °C

Temperature, Relative Humidity, Pressure

Dew Point

3.4 °F

1.9 °C

15-95% RH.

Refer to Range

for Temperature Sensor

0.1 °F

0.1 °C

Temperature, Relative Humidity

Heat Index

7.1°F

4.0°C

0.1 °F

0.1 °C

Temperature, Relative Humidity

Wet Bulb Temperature - Psychrometric

3.2 °F

1.8 °C

0.1 °F

0.1 °C

Temperature, Relative Humidity, Pressure

Wind Chill

1.6 °F

0.9 °C

0.1 °F

0.1 °C

Wind Speed, Temperature

ADDITIONAL PRODUCT INFO

Display Reflective LCD
Backlight Standard or dim red (NV models only) backlight. Manual activation with auto-off.
Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity.
Auto Shutdown After 45 minutes with no key presses.
Clock Real Time Hour:Minute Display
Certifications CE certified, RoHS and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Requires one CR2032 battery, included. Up to 300 hours of use, reduced by backlight use.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time n ecessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 4.8 x 1.9 x 1.1 in | 12.2 x 4.8 x 2.8 cm, 3.6 oz | 102 g (Including slip-on cover).

*Note: Accuracy calculated as uncertainty of the measurement derived from statistical analysis considering the combined effects from primary sensor specifications, circuit conversions, and all other sources of error using a coverage factor of k=2, or two standard deviations (2Ʃ)

**Note: These specifications are valid for all Kestrel 1000, 2000, 2500, 3000, 3500 series with a serial number higher than 2262687. If your product has a lower serial number, please reference the K4000 specifications 329011.

KESTREL 5000-5700 SERIES SPECIFICATIONS

KESTREL 5 SERIES SENSORS

SENSOR ACCURACY (+/-) RESOLUTION SPECIFICATION RANGE NOTES
Wind Speed |Air Speed Larger of 3% of reading, least significant digit or 20 ft/min 0.1 m/s 1 ft/min 0.1 km/h 0.1 mph 0.1 knots 1 B* 0.1 F/S* 0.6 to 40.0 m/s 118 to 7,874 ft/min 2.2 to 144.0 km/h 1.3 to 89.5 mph 1.2 to 77.8 knots 0 to 12 B* 2-131.2* 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH |7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller.
Ambient Temperature 0.9 °F 0.5 °C 0.1 °F 0.1 °C -20.0 to 158.0 °F -29.0 to 70.0 °C Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions.Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.
Relative Humidity 2%RH 0.1 %RH 10 to 90% 25°C non- condensing To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
Pressure 1.5 hPa|mbar 0.044 inHg 0.022 PSI 0.1 hPa|mbar 0.01 inHg 0.01 PSI 25°C/77°F 700-1100 hPa|mbar 20.67-32.48 inHg 10.15-15.95 PSI Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.
Compass 1° 1/16th Cardinal Scale 0 to 360° 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.

ADDITIONAL PRODUCT INFO

Display & Backlight Multifunction, multi-digit monochrome dot-matrix display. Choice of white or red LED backlight.
Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes.
Data Storage & Graphical display, Min/Max/Avg History Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
Data Upload & Bluetooth® Data Connect Option Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
Clock / Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Auto Shutdown User-selectable – Off, 15-60 minutes with no key presses.
Languages English, French, German, Spanish.
Certifications CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and built in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Life AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included)

KESTREL D1-D3 SERIES DROP SPECIFICATIONS

KESTREL DROP SENSORS

ACCURACY (+/-)

RESOLUTION

SPECIFICATION RANGE

NOTES

Ambient Temperature

0.9 °F

0.5 °C

0.1 °F

0.1 °C

14 to 131°F

-10 to 55 °C

Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions.

Calibration drift is negligible for the life of the product. For further details, see Battery Operational Temperature Limits.

Relative Humidity

2%RH

0.1 %RH

10 to 90% 25°C non- condensing

To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of

direct sunlight. Calibration drift is typically less than ±0.25% per year.

Pressure

1.5 hPa|mbar

0.044 inHg

0.022 PSI

0.1 hPa|mbar

0.01 inHg

0.01 PSI

25°C/77°F

700-1100 hPa|mbar

20.67-32.48 inHg

10.15-15.95 PSI

Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar

or below 10 mbar. Calibration drift is negligible for the life of the product.

CALCULATED MEASUREMENTS

MEASUREMENT

ACCURACY (+/-)

RESOLUTION

SENSORS EMPLOYED

Density Altitude

226 ft

69 m

1 ft

1 m

Temperature, Relative Humidity,

Pressure

Dew Point

3.4 °F

1.9 °C

15-95% RH. Refer to Range

for Temperature Sensor

0.1 °F

0.1 °C

Temperature, Relative Humidity

Heat Index

7.1°F

4.0°C

0.1 °F

0.1 °C

Temperature, Relative Humidity

THI (NRC)

1.5 °F

0.8 °C

0.1 °F

0.1 °C

Temperature, Relative Humidity

THI (Yousef)

2.3 °F

1.3 °C

0.1 °F

0.1 °C

Temperature, Relative Humidity

Wet Bulb Temperature - Psychrometric

3.2 °F

1.8 °C

0.1 °F

0.1 °C

Temperature, Relative Humidity

Pressure

ADDITIONAL PRODUCT INFO

Response Time & Display Update

Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15

minutes to reach 99% accuracy after exposure to large environmental changes.
Data Storage Logged history stored for every measured value. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. D1: >13,000 data points, D2: >7,000 data points, D3: >6,000 data points.
Bluetooth® Data Connect Option Wireless range up to 100ft|30m. Compatible with Kestrel LiNK app for iOS (model 4s and later) and select Android products (Android 4.3 and higher) (See website for complete list of compatible 3rd party apps).
Certifications CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery User-replaceable CR2032 (included).
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Battery Operational Temperature Limits 0° F to 140° F |-18 °C to 60 °C Measurements may be taken beyond the limits of the operational temperature range of batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F |-30.0 °C to 60.0 °C.
Size & Weight 2.4 x 1.8 x 0.9 in | 6 x 4.5 x 2.3 cm 1.2oz | 34g (Lithium battery included)

Kestrel 1,2,3 Manuals

Kestrel 5 Series Manuals

  • Kestrel 5000 Environmental Meter Quick Start Guide Download PDF
  • Kestrel 5100 Racing Weather Meter Quick Start Guide / Manual Download PDF
  • Kestrel 5200 Professional Environmental Meter Quick Start Guide Download PDF
  • Kestrel 5400 Heat Stress Quick Start Guide Download PDF
  • Kestrel 5500 Quick Start Guide / Manual | Download PDF
  • Kestrel 5700 & 5700 Elite Ballistics Meters Manual (html)
  • Kestrel Elite Weather Meters with Applied Ballistics Quick Start Guide / Manual | Download PDF
  • Kestrel 5000AG & 5400AG Agriculture and Livestock Meters User Guide | Download PDF
  • Kestrel 0854FWLVCORA, 0855FWLORA, 0855FWORA Fire Weather Meters | Download PDF
  • Kestrel Fire Weather FDFM, PIG Insert | Download PDF
  • Kestrel 5 Series Certificate of Conformity & Sensor Specifications Download PDF
  • How to UPDATE your Kestrel 5 Series Meter using Windows | Download PDF
  • Latest 5 Series Firmware Updates I Download PDF
  • Applied Ballistics Profile Loader for Windows PC

    Kestrel DROP Bluetooth Dataloggers

    Kestrel Accessories

    • How to replace your Kestrel Impeller I Download PDF


    Kestrel Dongle

    Get help connecting my Kestrel 5 series unit to my computer using a bluetooth dongle.

     


    Kestrel LiNK Overview

    Windows, Mac, iOS & Android Apps for Kestrel 5 Series Meters and Kestrel DROP's

    Kestrel LiNK Ballistics for Android & iOS (Series 5 Ballistics Meters)

    Wirelessly connect with mobile devices. When in range, manage and transfer gun profiles, adjust Kestrel target range, and view shooting solutions on the mobile device. Most effective when paired with the Kestrel Vane Mount for real-time windage solutions.

    Kestrel LiNK for Windows & Mac (Kestrel Series 5 Meters)

    Simple communication to Windows and Mac computers is provided through the optional LiNK .USB Dongle or USB Data Transfer Cable. Download your data to view, analyze and archive.  Enables firmware update of Kestrel 5 series meters.

    Kestrel LiNK for iOS & Android (Works with Series 5 Meters and Kestrel DROP's

    Wirelessly connect with iOS and Android devices.  When in range, view real-time measurements, receive on-screen alerts and download your data.  Logged data can be viewed, analyzed, archived and shared via e-mail, Facebook and Twitter.  Enables firmware update of Kestrel 5 series meters. NOTE:  Range up to 100’ line of sight – reduced by walls and obstructions.

     



    Blue Ocean Megaphone Manual


    Frequently asked questions

    FAQ's (Click Here)

    Discontinued Models Software & Manuals