Description
Kestrel 3500DT Delta-T Pocket Weather Meter – USA-Made, Essential Weather Data for Optimal Spraying Conditions – Waterproof, Floats, Includes 5-Year Warranty
The Kestrel 3500DT Delta-T Pocket Weather Meter is a professional-grade tool designed to provide accurate and comprehensive weather data, crucial for agricultural applications like crop spraying. Built in the USA, this reliable weather meter measures key environmental factors including wind speed, temperature, barometric pressure, relative humidity, dew point, and Delta-T—a critical value for assessing optimal spraying conditions. Whether you're a farmer, pest control professional, or field expert, the Kestrel 3500DT ensures you're always working within safe, effective conditions and helps you select the right spray nozzle for the job.
Why the Kestrel 3500DT is Perfect for Spraying Applications:
The Kestrel 3500DT Delta-T Pocket Weather Meter is specifically designed to help you assess optimal spraying conditions by measuring Delta-T and other critical environmental factors. By understanding Delta-T, you can ensure your spraying activities are within acceptable guidelines and choose the correct spray nozzle for optimal application, improving efficiency and reducing waste. Whether you're working in agriculture, pest control, or any outdoor setting, this meter provides all the data you need to make informed decisions for safer, more effective spraying.
Features
Sensor Specifications
Sensor Specifications
|
Wind Speed |
|
| Units of Measure: | mph | kt | B | m/s | ft/min / km/h |
| Specification Range: |
|
| Operational Range: |
|
| Resolution: |
|
| Accuracy (+/-): | Larger of 3% of reading, least significant digit or 20 ft/min |
| Notes: | 1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units. |
|
Ambient Temperature |
|
| Units of Measure: | Fahrenheit, Celsius |
| Specification Range: |
|
| Operational Range: |
|
| Resolution: |
|
| Accuracy (+/-): |
|
| Notes: | Hermetically sealed, precision thermistor mounted externally and thermally isolated (US Patent 5,939,645) for rapid response. Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. Calibration drift negligible. Thermistor may also be used to measure temperature of water or snow by submerging thermistor portion into material -- remove impeller prior to taking submerged measurements and ensure humidity sensor membrane is free of liquid water prior to taking humidity-based measurements after submersion. |
|
Pressure |
|
| Units of Measure: | inHg, hPA, mb |
| Specification Range: |
|
| Operational Range: |
|
| Resolution: |
|
| Accuracy (+/-): |
|
| Notes: | Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
|
Relative Humidity |
|
| Units of Measure: | % |
| Specification Range: | 5 to 95% 25°C non-condensing |
| Operational Range: | 0 to 100% |
| Resolution: | 0.1 %RH |
| Accuracy (+/-): | 3%RH |
| Notes: | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
Calculated Measurements
|
Barometric Pressure |
|
| Accuracy (+/-): |
|
| Resolution: |
|
| Sensors employed: |
|
|
Altitude |
|
| Accuracy (+/-): |
|
| Resolution: |
|
| Sensors employed: |
|
|
Dew Point |
|
| Accuracy (+/-): |
|
| Resolution: |
|
| Sensors employed: |
|
|
Wet Bulb Temperature - Psychrometric |
|
| Accuracy (+/-): |
|
| Resolution: |
|
| Sensors employed: |
|
|
Delta T |
|
| Accuracy (+/-): |
|
| Resolution: |
|
| Sensors employed: |
|